The In-Labeler Missing Label Detection System utilizes sensors mounted in the Labeler where the labels are precisely located for accurate inspection.

In-Labeler Label Inspection

In-Labeler Missing Label Detection

Missing labels have traditionally been detected using an array of photoeyes mounted between the Filtec inspection head and the rejector. Current systems work well for detecting most labels that are brightly colored and that wrap at least 90 degrees around the bottle. However, for many of today’s label applications such as dark, metallic, or labels that wrap less than 90 degrees, current systems are not adequate.

The In-Labeler Missing Label Detection System utilizes label detectors mounted in the Labeler where the labels are precisely located for accurate inspection. If a label is missing, this information is relayed downstream to the Filtec Rejection System where the faulty bottle is removed from the production line.

To address these tough applications, the new In-Labeler Missing Label Detection option is available for any new or existing Filtec Fill Level Inspection System.

Click here to download the Product Brochure in Adobe Acrobat format.Click here to download the Product Brochure in Adobe Acrobat format.

Features

bullet

Quick disconnect mounting brackets and cables for easy and repeatable installation/ removal for cleaning and quick change-overs.

bullet

Automatic "Learn Mode" to teach the system all the timing and tracking parameters needed to reliably track bottles from inside the Labeler to the Filtec Rejection System mounted downstream.

bullet

Automatic "Self Diagnostics" to alert the operator when any system component fails. Detailed instructions step the operator through the diagnostic process to quickly identify and correct problems for maximum performance and minimum downtime.

bullet

Multi-bottle memory allows the user to change-over for different bottle and label combinations with a few key strokes. Bottle types can be programmed into the system for added user friendliness.

bullet

Separate reject counters for each label to help identify Labeler problems.

bullet

Consecutive reject alarms provide immediate shutdown capability when too many rejects are detected. Separate alarm limits are provided for each label type being inspected. A "remote clear input" allows the alarm to be cleared remotely, eliminating the need for the operator to clear the alarm at the Filtec touch pad.

Features
(continued)

bullet

Data interface capability for providing throughput and reject counts to any PLC or PC based data acquisition system. Interface also allows for automatic change-over, clearing alarms, and transmitting diagnostic and line speed information.

bullet

Reject sorting assists the operator in reworking or discarding rejected bottles. When installed with multiple rejectors or with the new Servotec Rejection System, the system can sort the bottles with missing labels from the underfills, duds, etc.

bullet

Integration of other inspection systems to maximize the number of inspection functions that can be performed at the Labeler discharge. With the recent introduction of Dud (low pressure) Detectors on bottle lines, single file conveyor space for inspection and rejection at the Labeler discharge is often limited. The reject signal can easily be accepted from almost any external inspection device. The FT-50 allows the name of the device to be programmed on the display. A separate counter and alarm limit is also provided.

 

 

         